3030-10 HiTESTER
|
Basic tester with improved safety features

• Protected against transient voltages up to 250 V AC,
preventing electric shock accidents before they can happen
• Drop proof design withstands dropping onto a concrete floor from
a height of 1 meter
• LED check function
• Temperature measurement support (with optional probes)
CE marking
|
BASIC SPECIFICATIONS
|
DC Voltage
Range
|
0.3 V (16.7
k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V)
Accuracy: ±2.5 % f.s.
|
AC Voltage
Range
|
12 V (9 k-ohm/V)
Accuracy: ±4 % f.s.
30/120/300/600 V (9 k-ohm/V) Accuracy: ±2.5 % f.s. Average
rectifier effective value
|
Resistance
Range
|
0 to 3 k-ohm
( center scale 30 ohm), R × 1, R × 10, R × 100,
R × 1 k
Accuracy: ±3 % of scale length
|
DC Current
Range
|
60 µA/30
m/300 mA (300 mV internal voltage drop)
Accuracy: ±3 % f.s.
|
Other Functions
|
Battery
Check: 0.9 to 1.8 V, load resistance 10 ohm
Temperature: -20 to 150 °C ( 9021-01 Thermister Temperature
Probe is necessary, sold separately)
|
Safety Considerations
|
Complies
with EN61010-1:1992+A2:1995, EN61010-2-031:1994, Installation
Category III (anticipated transient overvoltage 6000 V),
Pollution Degree 2
|
Power Supply
|
R6P(AA) × 2
batteries
|
Dimensions,
mass
|
95 mm (3.74
in) W × 141 mm (5.55 in) H × 39 mm (1.54 in) D, 280
g (9.9 oz)
|
Accessories
|
9207 TEST LEAD (1), fuse
(1), 9390 CARRYING CASE (1)
|
|
|