3511-50 LCR HiTESTER

Compact & Powerful dedicated LCR measurement in 5 milli-second timeframes

• High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz)
• High precision accuracy: ±0.08 %
• Built-in comparator

BASIC SPECIFICATIONS

Measurement Parameters

|Z|, phase angle, C, L, D, Q, R

Measurement Method

Source: constant voltage 50 mV to 1 V rms (AC)
Sense: voltage, AC

Source Frequency

120 Hz or 1 kHz

Measurement Ranges

|Z|, R: 10 m-Ohm to 200.00 M-Ohm (depending on condition)
phase angle: -90.00 to +90.00°
C: 0.940 pF to 999.99 mF
L: 1.600 µH to 200.00 kH
D: 0.0001 to 1.9900
Q: 0.85 to 999.99

Basic Accuracy

|Z|: ±0.08 % rdg.
phase angle: ±0.05°

Measurement Times

Fast: 5 msec. to Slow: 300 msec.(at 1 kHz)
Fast: 13 msec. to Slow: 400 msec.(at 120 Hz)

Display

99999 full digits, LED

Comparator Functions

Setting: Upper and lower limit, absolute value
Output: 3 levels (Hi, In, Lo), Open-collector, Isolated

External Printer

9442 (use with the 9443-02 or -03/9444)

Power Supply

100 to 240 V AC (selectable type), 50/60Hz

Dimensions, mass

210 mm(8.27 in)W × 100 mm(3.94 in)H × 168 mm(6.61 in)D, 2.5 kg (88.2 oz)

Accessories

Power cord(1), Fuse(1)

s 

 

3522-50 LCR HiTESTER

Impedance meter with a wide test frequency range

The measurement frequency can be freely adjusted with four-digit precision in a wide range from 42 Hz to 5 MHz. In particular, this makes it easy to test sample characteristics in the high frequency range. Operation is extremely simple; touch the item on the screen to be changed, and the possible settings appear in sequence.

BASIC SPECIFICATIONS

Measurement Parameters

|Z|, |Y|, phase angle, Rp, Rs(ESR), G, X, B, Cp, Cs, Lp, Ls, D (dissipation factor), and Q

Measurement Method

Source: constant current 10 µA to 100 mA (42 Hz to 1 MHz), 50 µA to 20 mA (1 MHz to 5 MHz), or constant voltage 10 mV to 5 V (42 Hz to 1 MHz), 50 mV to 1 V (1 MHz to 5 MHz)
Sense: voltage, AC

Source Frequency

42 Hz to 5 MHz

Measurement Ranges

|Z|, R, X: 10.00 m-Ohm to 200.00 M-Ohm (depending on condition)
phase angle: -180.00 to +180.00°
C: 0.3200 pF to 370.00 mF
L: 16.000 nH to 750.00 kH
D: 0.00001 to 9.99999
Q: 0.01 to 999.99
|Y|, G, B: 5.0000 nS to 99.999 S

Basic Accuracy

|Z|: ±0.08 % rdg.
phase angle: ±0.05°

Measurement Times
Typical Values for Displaying

|Z| Fast: 5 msec. to Slow2: 140 msec.

Display

99999 full digits, LCD with backlight display

Comparator Functions

Setting: Upper and lower limit, percentage, or absolute value, Output: 3 levels (Hi, In, Lo), Open-collector, Isolated

External Printer

9442 (use with the 9443-02 or -03/9446/9593-01)

Power Supply

100 to 240 V AC (selectable type), 50/60Hz

Dimensions, mass

352 mm (13.86 in) W × 124 mm (4.88 in) H × 323 mm (12.72 in) D, 6.5 kg (229.3 oz)

Accessories

Power cord (1), Fuse (1)

s 

 

3532-50 LCR HiTESTER

Impedance meter with a wide test frequency range

The measurement frequency can be freely adjusted with four-digit precision in a wide range from 42 Hz to 5 MHz. In particular, this makes it easy to test sample characteristics in the high frequency range. Operation is extremely simple; touch the item on the screen to be changed, and the possible settings appear in sequence.

BASIC SPECIFICATIONS

Measurement Parameters

|Z|, |Y|, phase angle, Rp, Rs(ESR), G, X, B, Cp, Cs, Lp, Ls, D (dissipation factor), and Q

Measurement Method

Source: constant current 10 µA to 100 mA (42 Hz to 1 MHz), 50 µA to 20 mA (1 MHz to 5 MHz), or constant voltage 10 mV to 5 V (42 Hz to 1 MHz), 50 mV to 1 V (1 MHz to 5 MHz)
Sense: voltage, AC

Source Frequency

42 Hz to 5 MHz

Measurement Ranges

|Z|, R, X: 10.00 m-Ohm to 200.00 M-Ohm (depending on condition)
phase angle: -180.00 to +180.00°
C: 0.3200 pF to 370.00 mF
L: 16.000 nH to 750.00 kH
D: 0.00001 to 9.99999
Q: 0.01 to 999.99
|Y|, G, B: 5.0000 nS to 99.999 S

Basic Accuracy

|Z|: ±0.08 % rdg.
phase angle: ±0.05°

Measurement times
typical values for displaying

|Z| Fast: 5 msec. to Slow2: 140 msec.

Display

99999 full digits, LCD with backlight display

Comparator Functions

Setting: Upper and lower limit, percentage, or absolute value, Output: 3 levels (Hi, In, Lo), Open-collector, Isolated

External Printer

9442 (use with the 9443-02 or -03/9446/9593-01)

Power Supply

100 to 240 V AC (selectable type), 50/60Hz

Dimensions, mass

352 mm (13.86 in) W × 124 mm (4.88 in) H × 323 mm (12.72 in)D, 6.5 kg (229.3 oz)

Accessories

Power cord (1), Fuse (1)

s 

 

3535 LCR HiTESTER

LCR meter with the broad frequency range of 100kHz to 120MHz

Measure across the broad frequency range of 100kHz to 120MHz with 3535 LCR HiTESTER. The 6ms high-speed measurement capability is particularly useful with the built-in comparator and load functions, and for BIN (classification) measurements, to suit a wide range of applications such as chip inductor and high speed magnetic head testing, as well as other related research needs. Achieve ultimate measurement flexibility by detaching the head amp unit from the main unit and placing it in proximity to the test object so as to minimize the effect of test leads on measurements.

BASIC SPECIFICATIONS

Measurement Parameters


5 mV to 20 V/division, 12 ranges (20 division f.s.)
resolution: 1/80 of range
AC voltage for possible measurement/ display using the memory function: 280 Vrms

Measurement Signal Level

Open-terminal voltage mode:
5 mV to 1 V, 20mA max. (up to 10.00 MHz)
5 mV to 500 mV, 10 mA max.
(above 10.01 MHz)
Constant Current mode:
200 µA to 20 mA, 1 V max.
(up to 10.00 MHz)
200 µA to 10 mA, 0.5 V max.
(above 10.01 MHz)

Measurement Frequency

100 kHz to 120 MHz

Measurement Range

9700-01 HEAD AMP UNIT:
100 m-ohm to 1 k-ohm
9700-02 HEAD AMP UNIT:
100 ohm to 10 k-ohm
9700-03 HEAD AMP UNIT:
1 k-ohm to 100 k-ohm
A Heap Amp Unit and Test Fixture are not supplied with the unit. Please select the Head Amp and the Test Fixture options for your application.
Head Amp Unit must be factory adjusted for dedicated use with the main unit before delivery.

Measurement Time

6 ± 1 msec.

Comparator Functions

Upper and lower limit
absolute value or percentage

Power Supply

100 to 240 V AC, 50/60Hz

Dimensions, mass

360 mmW × 130 mm (H) × 360 mm (D), 8.3 kg

s 

 

3560 AC m-Ohm HiTESTER

For measurement requirements from contact resistance to internal resistance and voltage of batteries

The instrument also features an Ohm and V mode that allows simultaneous measurement and comparison of battery internal resistance and open-circuit voltage. It is highly suitable for battery inspection lines as one unit can act as both a low-resistance meter and DMM.

BASIC SPECIFICATIONS

Measurement Ranges and Accuracy

30 m-Ohm to 3 k-Ohm, 6 ranges, ±0.5 % rdg. ±8 dgt. (all ranges)
In the case of MEDIUM: Add 3 dgt. to the above dgt. error
In the case of FAST: ±0.5 % rdg. ±8 dgt. (30 m-Ohm), ±0.5 % rdg. ±6 dgt. (other ranges)
However, in the case of FAST, the display counter decreases 4 digits in all ranges.

Measurement Current

7.4 mA (30 m-Ohm range) to 1.5 ƒÊA (3 k-Ohm range)

Max. Applied Measurement Voltage

60 V DC (AC input is not possible)

Sampling Speed

50 times/s (FAST) to 1.56 times/s (SLOW) at 50 Hz mode
60 times/s (FAST) to 1.88 times/s (SLOW) at 60 Hz mode

Display

31,000 full digits (resistance), 50,000 full digits (voltage), Fluorescent tube

Measurement Method

1 kHz AC four-terminal measurement

Open-Circuit Terminal Voltage

20 mV peak max. (30 m-Ohm to 3 k-Ohm all ranges)

Comparator Functions

Setting: Upper and lower limit, Up to 30 tables
Output: 3 levels (Hi, In, Lo) or (Pass, Fail), Open-collector, display, beep sound

Interface

RS-232C (standard), GP-IB or External printer (option)

Power Supply

100 to 240 V AC (50/60 Hz)

Dimensions, mass

215 mm (8.46 in) W × 80 mm (3.15 in) H × 320 mm (12.6 in) D, 2.1 kg (74.1 oz)

Accessories

9287 CLIP-TYPE LEAD(1), Power cord(1)

 

 