s 

 

3634-20 INSTRUMENTATION LOGGER
CURRENT (AC/DC)

Instrument (DC current) data collection

• Up to 16,000 measurement data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Instrumentation (0 to 20 mA DC)

Input Channels

1 channel

Measurement Range

0.00 to 20.00 mA

Accuracy

±0.8 % rdg. ±5 dgt.

Data memory

16000 data
(60 minutes interval, total 667 days)

Recording Interval

2 to 30 seconds, 1 to 60 minutes, 14 settings

Power Supply

2 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 2 years (recording interval 1 minute)

Dimensions, mass

57 mm (2.24 in) W × 74 mm (2.91 in) H × 19.5 mm (0.77 in) D, 70 g (2.5 oz)

Accessories

LR03 alkaline dry cell batteries (2), 9632 CONNECTION CABLE (1)

s 

 

3636-20 CLAMP LOGGER
CURRENT (AC/DC)

Easy and convenient, clamp-on current recording

• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Effective value rectifier method for correct measurement
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

AC Current
(with clamp-on sensor, sold separately)

Input Channels

2 channels

Measurement Range

0.00 to 50.00 A, 0.0 to 500.0 A (True RMS)

Accuracy

±2.5 % rdg. ±8 dgt. (at 50/60 Hz, combined accuracy with clamp-on sensor)

Data Memory

16000 data × 2ch
(1-minute interval, total 11 days)
32000 data × 1ch
(1-minute interval, total 22 days)

Recording interval

1 to 30 seconds, 1 to 60 minutes, 15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 year
(recording interval 1 minute)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9632 CONNECTION CABLE (for alarm output, 1)

s 

 

3638-20 LEAK LOGGER
CURRENT (AC/DC)

Recording and Monitoring Leak Current

• Select from three types of clamp-on leak current sensors
• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Effective value rectifier method for leak current measurement
Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Parameters

AC leak current (with clamp-on leak sensor, sold separately)

Input Channels

2 channels

Measurement Range

100.0 mA, 1000 mA (True RMS)

Combined Accuracy

With 9657 or 9659 sensor: ±2 % rdg. ±10 dgt. (at 50/60 Hz)
With 9658 sensor: ±4.5 % rdg. ±10 dgt. (at 50/60 Hz)

Data Memory

16000 data × 2ch
(1-minute interval, total 11 days)
32000 data × 1ch
(1-minute interval, total 22 days)

Recording Interval

1 to 30 seconds, 1 to 60 minutes, 15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 month (recording interval 1 second)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9632 CONNECTION CABLE (for alarm output, 1)

s 

 

3640-20 LUX LOGGER
LUMINANCE

For super easy logging of luminance! Use as a scale to improve the job environment, conserve energy, record the level of sun exposure,and much more.

• Record luminance for improved working environments or energy conservation
• For a scale to determine exposure to the sun for agriculture
• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Illumination
(with 9662 LUX SENSOR use, included)

Input channels

1 channel

Measurement Range

0 to 2000lx / 20000lx / 200000lx, Manual range (Select when recording is stopped)

Accuracy

±4 % rdg. ±5 dgt.
(unit + sensor, after zero adjust)

Data Memory

32000 data × 1ch
(1-minute interval, total 22 days)

Recording Interval

1 to 30 seconds, 1 to 60 minutes, 15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 year (recording
interval 1 minutes, power conservation function is ON)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9662 LUX SENSOR (for measurement, 1)

s 

 

3639-20 PULSE LOGGER
PULSE

Pulse Totalizer for Hygrometers, Flowmeters and Powermeters

• Accumulates up to 9,999 counts
• Noise filtering to minimize the possibility of miscounts
• Alarm output provided (with selectable threshold)
• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrumentfs memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Pulse Input
No-voltage input connection (e.g., switch or relay) counts when contact across terminals
changes from short to open
Voltage input: +1.5 to 45 V high, 0 to 0.2 V low (logic state is undetermined between 0.2 and 1.5 V)
A count occurs when voltage level becomes high

Input Channels

1 channel

Measurement Range

Display: 9,999 counts/interval, "OF" is displayed for 10,000+ counts
(internal data is also "OF")

Accuracy

±1 dgt. or better

Data Memory

32000 data x 1ch
(1-minute interval, total 22 days)

Recording interval

1 to 30 seconds, 1 to 60 minutes, 1 day, 16 settings

Power Supply

4 x 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 3 months (recording interval 10 minutes)

Dimensions, mass

57.5 mm (2.26 in) W x 86.5 mm (3.41 in) H x 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4),
9629 CONNECTION CABLE
(for measurement input, 1),
9632 CONNECTION CABLE
(for alarm output, 1)

s 

 

3635-24/-25/-26 VOLTAGE LOGGER
VOLTAGE

DC voltage data collection

• Up to 16,000 measurement data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

DC Voltage

Input Channels

1 channel

Measurement Range

3635-24: -500.0 mV to 500.0 mV
3635-25: -5.000 V to 5.000 V
3635-26: -50.00 V to 50.00 V

Accuracy

3635-24/-25/-26: ±0.8 % rdg. ±5 dgt.

Data Memory

16000 data
(60 minutes interval, total 667 days)

Recording Interval

2 to 30 seconds, 1 to 60 minutes,
14 settings

Power Supply

2 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 2 years (recording interval 1 minute)

Dimensions, mass

57 mm (2.24 in) W × 74 mm (2.91 in) H × 19.5 mm (0.77 in) D, 70 g (2.5 oz)

Accessories

LR03 alkaline dry cell batteries (2), 9632 CONNECTION CABLE (1)

s 

 

3637-20 AC VOLTAGE LOGGER
VOLTAGE

Easy and convenient, low-cost voltage recording

• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Effective value rectifier method for correct measurement
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

AC Voltage

Input Channels

1 channel

Measurement Range

0.0 to 600.0 V (True RMS)

Accuracy

±1 % rdg. ±5 dgt. (at 50/60 Hz)

Data Memory

32000 data × 1ch
(1-minute interval, total 22 days)

Recording interval

1 to 30 seconds, 1 to 60 minutes,
15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 year
(recording interval 1 minute)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9639 CONNECTION CORD
(for measurement input, 1)

s 

 

3645-20 VOLTAGE LOGGER
VOLTAGE

Record Output from Sensors and
Measuring Instruments

• Records output of sensors requiring preheating
• Analog Output recording of measuring instruments
• One unit can handle a variety of outputs (Ranges from DC 50 mV, 500 mV, 5V, 50 V)
• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

DC Voltage with Any Sensor
(power control function for sensors)

Input Channels

1 channel

Measurement Range

±50.00 mV / ±500.0 mV / ±5.000 V / ±50.00 V

Accuracy

±0.5 % rdg. ±5 dgt.

Data Memory

32000 data × 1ch
(1-minute interval, total 22 days)

Recording Interval

1 to 30 seconds, 1 to 60 minutes,
15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 140 days (recording interval 1 minutes, preheat is 5 seconds, power conservation function is OFF)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9632 CONNECTION CABLE (for output, 1), 9639 CONNECTION CORD (for input, 1)

s 

 

3634-20 INSTRUMENTATION LOGGER
VOLTAGE

Instrument (DC current) data collection

• Up to 16,000 measurement data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Instrumentation (0 to 20 mA DC)

Input Channels

1 channel

Measurement Range

0.00 to 20.00 mA

Accuracy

±0.8 % rdg. ±5 dgt.

Data Memory

16000 data
(60 minutes interval, total 667 days)

Recording Interval

2 to 30 seconds, 1 to 60 minutes,
14 settings

Power Supply

2 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 2 years (recording interval 1 minute)

Dimensions, mass

57 mm (2.24 in) W × 74 mm (2.91 in) H × 19.5 mm (0.77 in) D, 70 g (2.5 oz)

Accessories

LR03 alkaline dry cell batteries (2),
9632 CONNECTION CABLE (1)

s 

 

3636-20 CLAMP LOGGER
VOLTAGE

Easy and convenient, clamp-on current recording

• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Effective value rectifier method for correct measurement
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

AC Current
(with clamp-on sensor, sold separately)

Input Channels

2 channel

Measurement Range

0.00 to 50.00 A, 0.0 to 500.0 A (True RMS)

Accuracy

±2.5 % rdg. ±8 dgt. (at 50/60 Hz, combined accuracy with clamp-on sensor)

Data Memory

16000 data × 2ch
(1-minute interval, total 11 days)
32000 data × 1ch
(1-minute interval, total 22 days)

Recording Interval

1 to 30 seconds, 1 to 60 minutes,
15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 year
(recording interval 1 minute)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9632 CONNECTION CABLE (for alarm output, 1)

s 

 

3638-20 LEAK LOGGER
VOLTAGE

Recording and Monitoring Leak Current

• Select from three types of clamp-on leak current sensors
• Up to 32,000 measurements data can be collected with the optional 3911-20 for processing by PC
• Effective value rectifier method for leak current measurement
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement items

AC leak current
(with clamp-on leak sensor, sold separately)

Input Channels

2 channel

Measurement Range

100.0 mA, 1000 mA (True RMS)

Combined Accuracy

With 9657 or 9659 sensor:
± 2 % rdg. ±10 dgt. (at 50/60 Hz)
With 9658 sensor:
± 4.5 % rdg. ±10 dgt. (at 50/60 Hz)

Data Memory

16000 data × 2ch
(1-minute interval, total 11 days)
32000 data × 1ch
(1-minute interval, total 22 days)

Recording Interval

1 to 30 seconds, 1 to 60 minutes,
15 settings

Power Supply

4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 month (recording interval 1 second)

Dimensions, mass

57.5 mm (2.26 in) W × 86.5 mm (3.41 in) H × 30 mm (1.18 in) D, 130 g (4.6 oz)

Accessories

LR03 alkaline dry cell batteries (4), 9632 CONNECTION CABLE (for alarm output, 1)

s 

 

3632-20 TEMPERATURE LOGGER
TEMPERATURE/HUMIDITY

Temperature data collection

• The 3632 is completely waterproof (The unit is not designed for continuous immersion)
• Up to 16,000 measurement data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Temperature (internal sensor only)

Input Channels

1 channel

Measurement Range

-20.0 °C to 70.0 °C (when using the internal temperature sensor)

Accuracy

±0.5 °C (at 0.0 to 35.0 °C), or other

Data Memory

16000 data
(60 minutes interval, total 667 days)

Recording Interval

2 to 30 seconds, 1 to 60 minutes,
14 settings

Power Supply

2 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 2 years (recording interval 1 minute)

Dimensions, mass

57 mm (2.24 in) W × 74 mm (2.91 in) H × 19.5 mm (0.77 in) D, 70 g (2.5 oz)

Accessories

LR03 alkaline dry cell batteries (2)

s 

 

3633-20 TEMPERATURE LOGGER
TEMPERATURE/HUMIDITY

Temperature data collection

• Up to 16,000 measurement data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Temperature (internal sensor only)

Input Channels

1 channel

Measurement Range

-20.0 °C to 70.0 °C (when using the internal temperature sensor), -40.0 °C to 180.0 °C (when using the external temperature sensor)

Accuracy

±0.5 °C (at 0.0 to 35.0 °C), or other

Data Memory

16000 data
(60 minutes interval, total 667 days)

Recording Interval

2 to 30 seconds, 1 to 60 minutes,
14 settings

Power Supply

2 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 2 years (recording interval 1 minute)

Dimensions, mass

57 mm (2.24 in) W × 74 mm (2.91 in) H × 19.5 mm (0.77 in) D, 70 g (2.5 oz)

Accessories

LR03 alkaline dry cell batteries (2)

s 

 

3641-20 HUMIDITY LOGGER
TEMPERATURE/HUMIDITY

For temperature and humidity data logging!

• Up to 16,000 measurement data can be collected with the optional 3911-20 for processing by PC
• Special software bundled with the 3911-20 enables storing of the recording time, interval, start, end, method and comments in the instrument's memory
• Non-volatile memory preserves collected data even when the battery is depleted

BASIC SPECIFICATIONS

Measurement Items

Temperature (internal sensor only)

Input Channels

2 channels (2ch alternating measurement)

Measurement Range

Temperature: -20.0 °C to 70.0 °C (when using the internal temperature sensor), -40.0 °C to 180.0 °C (when using the external temperature sensor), -40.0 °C to 85.0 °C
(when using the 9680 humidity sensor)
Humidity: 0.0 % to 100.0 % rh
(when using the 9680 humidity sensor)

Accuracy

Temperature: ±0.5 °C
(at 0.0 to 35.0 °C), or other
Humidity: ±5 % rh (at 25 °C)

Data Memory

8000 data × 2ch (temperature, humidity, 60-minute intervals, total 333 days)

Recording Interval

2 to 30 seconds, 1 to 60 minutes,
14 settings

Power Supply

2 × 1.5 V, LR03 (AAA) alkaline dry cell batteries, lifetime approx. 1 year
(recording interval 1 minute)

Dimensions, mass

57 mm (2.24 in) W × 74 mm (2.91 in) H × 19.5 mm (0.77 in) D, 70 g (2.5 oz)

Accessories

9680 HUMIDITY SENSOR (1), LR03 alkaline dry cell batteries (2)

s 

 

3650 TEMPERATURE LOGGER
TEMPERATURE/HUMIDITY

Tiny button-sized temperature logger

• Sensor, memory and battery are all included in one 17.35 mm(0.68 in) diameter unit
• The -40 to 85 °C measurement range supports the temperature control requirements for processes conforming to HACCP guidelines
• Collects up to 2,048 temperature measurements (about one year at 4 hr 15 minutes intervals)
• PC processes such as data graphing can be performed by using the optional reader to collect temperature data

BASIC SPECIFICATIONS

Measurement Items

Temperature (internal sensor only)

Input Channels

1 channel

Measurement Range

-40.0 °C to 85.0 °C

Accuracy

±1.5 °C (at -10.0 to 30.0 °C), or other

Data Memory

2048 data, Max. recording times: Approx. 1 year at 4 hours and 15 minutes recording period

Recording Interval

1 minute to 255 minutes

Power Supply

Internal battery, lifetime approx. 4 years (recording interval 5 minutes)

Dimensions, mass

17.35 mm (0.68 in) diameter × 5.89 mm (0.23 in) thickness, 3.3 g (0.1 oz)

Accessories

Holder (1)

 

 
Copyright © 2004-2006 Solcom, Inc. All rights Reserved.